Prismatic cells OCV testing system
Technical profile
Equipment photo
Ⅰ.System introduction
The equipment consists of a testing fixture, testing system, rack cabinet, etc. The battery is manually loaded into the fixture after scanning the code. The device automatically scans the code and tests the corresponding internal resistance voltage and level information, which is retained in the local system.
Ⅱ.System composition
The testing structure consists of a battery fixture below and a probe pressing module above. The fixture can be manually adjusted according to the size of the battery, and the probe module above can also be adjusted as a whole based on the height of the battery
1. 65-170mm The fixture can test the range of electrode pole spacing between 65-170mm
2.Testable length 75mm-200mm
Ⅲ.Equipment workflow
Ⅳ.Technical parameters
4.1 Equipment operating environment requirements
4.1.1 Working temperature range:25℃±5℃
4.1.2 Temperature:≤85%
4.1.3 Venue: No pollution and strong electromagnetic interference
4.1.4 Maximum device size L: 1000mm;W: 620mm; H: 1450mm
4.1.5 Net weight:About 400kg.
4.1.6 Power supply:AC220V±10% 50Hz;power consumption≤1000W
4.1.7 Compressed air: pressure of 0.5~0.7Mpa
4.2 System technical indicators
4.2.1 Probability of damaging the product:≤0.1%
4.2.2 Equipment capacity/speed:≥20PPM
4.2.3 NG equipment failure rate:≤1%(Malfunctions caused solely by equipment)
4.2.4 PC:1 Set
4.2.5 Equipment main switch: CHINT leakage protection switch
Ⅴ.Main accessories